Download AG31-004 - School HVAC Design Manual by McQuay PDF

By McQuay

Show description

Read or Download AG31-004 - School HVAC Design Manual PDF

Similar technique books

Fabric Energy Storage

This file offers advice at the use of establishing textile as a garage medium for heating and cooling power transported by way of circulating air. specific realization is paid to using concrete slabs for garage of loose cooling on hand from low ambient in a single day air temperature. This paintings contains an advent to the concept that of material power garage and a dialogue of layout issues.

Service Engineering: Entwicklung und Gestaltung innovativer Dienstleistungen, 2.Auflage

Die schnelle und effiziente Realisierung innovativer Dienstleistungen stellt zunehmend einen Erfolgsfaktor für die Wettbewerbsfähigkeit von Dienstleistungsunternehmen dar. Dienstleistungen werden in der Praxis jedoch oft "ad hoc", d. h. ohne systematische Vorgehensweise, entwickelt. Das Konzept des "Service Engineering" beschreibt Vorgehensweisen, Methoden und Werkzeugunterstützung für die systematische Planung, Entwicklung und Realisierung innovativer Dienstleistungen.

Auctions, Market Mechanisms and Their Applications: First International ICST Conference, AMMA 2009, Boston, MA, USA, May 8-9, 2009, Revised Selected Papers ... and Telecommunications Engineering)

This booklet constitutes the completely refereed post-conference complaints of the 1st overseas ICST convention on Auctions, marketplace Mechanisms and Their functions, AMMA 2009, held in Boston, MA, united states, in could 2009. The sixteen revised papers offered have been rigorously reviewed and chosen from 38 submissions.

Extra info for AG31-004 - School HVAC Design Manual

Sample text

In doing so, it is indifferent to uneven flow profiles, air turbulence, and pressure variations. Dependant vs. Independent Systems VAV systems can be either dependent or independent. The difference is mostly in the VAV box design. Dependent VAV boxes modulate the damper position in proportion to the cooling load. Independent VAV boxes modulate the air volume in proportion to the cooling load. Independent VAV boxes can measure the amount of air passing through them while dependent VAV boxes cannot.

The air-handling unit should be selected and the ductwork designed for 6,000 cfm with a diversity of 83%. It is not an uncommon practice to “default” to a minimum cfm/ft2 and design the air system based on this airflow while applying diversity to the cooling plant (chiller) size. This practice should be discouraged, as it will result in an oversized air handler and ducting. Even worse, the cooling load calculated from the air handling unit psychrometrics and the cooling load from the load estimation won’t match.

Some Multizone systems simultaneously mix cooled air and heated air to meet the requirements of the zone. While they were very popular in schools during the 1970s, many systems have reached the end of their useful life and needed to be replaced. 2) to existing buildings. 1-1999 compliance should be taken into consideration. There several exceptions allowed by the Standard. It is recommended that the readers familiarize themselves with this section of the Standard. Application Guide AG 31-004 37 Heating and Ventilating Systems Heating and ventilating systems are the most basic central system.